We’re pleased to inform you that NSN part number RF9009-2 is now available in our ready-to-ship inventory. NSN part number RF9009-2 is a Filter Radio Frequency Interfere with NSN 5915011698178 and manufactured by Ems Development Corporation (CAGE Code 13619). We can get you one of the fastest and most competitive quotes on the market for NSN part number RF9009-2 in just 15 minutes. Are you interested? All you have to do is fill out the Request for Quote (RFQ) provided here.
As you fill out the RFQ, make sure that all fields, especially the asterisk-marked (*) ones like Need Parts By and Quantity (ea), are completely filled out. We will be using your response to these fields in order to understand your requirements and calculate your RFQ accordingly.
Note : We Will Not Share Your Information To Any Third Parties.
ASAP Supply Chain, owned and operated by ASAP Semiconductor, is a leading distributor of Ems Development Corporation NSN parts and accessories in the United States. We have an inventory of more than 2 billion parts, new and obsolete, and shipping centers all across the United States, allowing us to get our customers the parts they need as soon as they need them. Our shipping center is located in Anaheim, California.
National Stock Numbers, or NSNs, are 13-digit serials assigned to all items that bought, stocked, and issued via the federal supply chain by the Defense Logistics Agency (DLA). Are you interested in learning more about NSN 5915-01-169-8178 or NSNs in general? Feel free to call us at our toll-free number, +1 (714) 705-4780, or email us at sales@asap-supplychain.com. And for a faster and more convenient purchasing solution, check out the ASAP Semiconductor App on Google Play or the App Store.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-169-8178 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 011698178 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
NF21154-2 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.490 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.830 INCHES NOMINAL |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.180 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.580 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.880 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 100.0 TO 350.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.880 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -28.0 TO 70.0 DEG CELSIUS |
AFSV | AVERAGE LIFE RATING IN HOURS | 92000.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION400.0 2ND RADIO INTERFERENCE 2ND FUNCTION400.0 3RD RADIO INTERFERENCE 3RD FUNCTION400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.4 1ST RADIO INTERFERENCE 1ST FUNCTION5.4 2ND RADIO INTERFERENCE 2ND FUNCTION5.4 3RD RADIO INTERFERENCE 3RD FUNCTION1.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION1.15 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 49956 |
AHBP | INPUT TERMINAL IDENTIFICATION | MS27467T15B97S |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CBBL | FEATURES PROVIDED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION1 TURRET GROUND 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
CQRG | BODY MATERIAL | ALUMINUM |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 322.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
FEAT | SPECIAL FEATURES | FOUR FILTERED FUNCTIONS TWO UNFILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
Industry's Fastest RFQ Turnaround. Get Your Parts Quote Now.
Email Your Requirement at:
sales@asap-supplychain.com
Million
Parts Sold
Million
Parts Avalilable
Thousand
Happy Customers
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |